by Administrator | Apr 17, 2018 | Uncategorized
Beckman Group 1 tested the plate with 1:1, 2:1, 3:1, 4:1 ratios of iron to aluminum since they increased the amount of aluminum last time so they can compare the effects of increasing ratio of iron to aluminum to effects of increasing aluminum to iron. Group 2 tested...
by Administrator | Mar 20, 2018 | Uncategorized
Beckman Group 1 started baking their plate (BHS-1-52). This plate had 0.03 M of iron standard and 0.03 M of Al(NO3)3. The ratios of Al: Fe are 4:1, 3:1, 2:1, and 1:1. They are also going to make another plate similar to BHS-1-52 but will increase the ratio of iron...
by Administrator | Mar 13, 2018 | Uncategorized
Beckman Group 1 is spotting a plate with ratios of iron (III) nitrate to aluminum nitrate. Their plate, 1-52, will have four different ratios of iron (III) nitrate to aluminum nitrate—1:1, 1:2, 1:3, and 1:4, each ratio having their own section on their plate. Group 2...
by Administrator | Feb 25, 2018 | Uncategorized
In order to be able to run more plates and become more efficient in the long run, Beckman decided to install the SEAL Kit Software onto another computer. Because it took time, it was too late to run any plates this week. After researching and looking through previous...
by Administrator | Feb 21, 2018 | Uncategorized
Beckman Group 1 created a sodium sulfite solution for testing. Because the epoxy has proven to be weaker when being put into the testing solution after five to ten minutes of drying, they are waiting for 45 minutes for it to dry before testing. Group 2 is testing a...
by Administrator | Feb 12, 2018 | Uncategorized
It’s been a slow few weeks so I combined the updates into one post. Poly tested two MnCaO and two MnVO plates but didn’t report on the results (not good?). They also wanted to try a different method of pre-cleaning plates to allow for better results, so...